INSTRUMENT SUNSHADES
WEATHERPROOF POLYESTER GRP INSTRUMENT SUNSHADE
Our Fantastic Sunshades are designed to protect instruments, switches & other equipments. Instrument sunshades provide a high degree of protection from excess temperature rises that might cause a drift in measurement accuracy. It also protects your equipment from rain, dust and accidental impact.
The sunshade can provide environmental protection required for some applications. Our sunshades come in different varieties of measurement and shape. We also accept customized orders where required from our clients.
Polyester GRP and Stainless-Steel Instrument Sunshades
Instrument sunshades are used to protect instruments from weather elements at Oil & Gas sites. Sunshades provide a high degree of protection to field equipment and applications from excess temperature rises that might cause a drift in measurement accuracy, as well as rain, dust and accidental impact. Sunshades provide all the environmental protection required for some applications. These sunshades can be customised to fit transmitters and gauges when combined with different variety of heavy-duty mounts.
FanTastic sunshades come in different variance of measurement and shape. We do accept customised order as required.
STANDARD FEATURES
Fire Retardant
Corrosion Resistant
UV-Resistant
Water Resistant
Chemical Resistant
Heat Resistant
POLYESTER GRP INSTRUMENT SUNSHADES
Mechanical Data
Test | Units of Measure | Nominal | Test Method |
Tensile Strength | psi/MPa | 12,500/86 | ASTM D 638 |
Flexural Strength | psi/MPa | 21,300/147 | ASTM D 790 |
Tensile Modulus | psi/GPa | 520,000/3.6 | ASTM D 638 |
Flexural Modulus | Psi/GPa | 530,000/3.7 | ASTM D 790 |
Tensile Elongation | % | 4.7 | ASTM D 638 |
Heat Distortion Temperature | °F/°C@ 264 psi | 241/116 | ASTM D 648 |
Barcol Hardness | 39 | ASTM D 2583 |
Standard colour is RAL 7035 (Light Grey). Other colours on request.
Measurement
STAINLESS STEEL INSTRUMENT SUNSHADES
Mechanical Data
Grade | Tensile Strength | Yield Strength 0.2% Proof | Elogation | Hardness | |
(MPa)min | (MPa)min | (% in 50mm)min | Rockwell B (HR B) max | Brinell (HB) max | |
316 | 515 | 205 | 40 | 95 | 217 |